Reduce downtime - find leakage currents without taking equipment offline
Fluke 368 FC
Specifications
Measurement Function Alternating current
AC Ampere Range 3, 30, 300 mA
3, 30, 60 A
Range Selection mA/A: Manual selection
3/30/300 mA: Automatic selection
3/30/60 A: Automatic selection
Range/Resolution 3/0.001 mA
30/0.01 mA
300/0.1 mA
3/0.001 A
30/0.01 A
60/0.1 A
Accuracy - Filter Activated (40 to 70 Hz), Filter Off (40 to 1 kHz) 3 mA to 30 A: 1% + 5 digits
60 A: 2% + 5 digits
Frequency 40 Hz to 1 kHz
Crest Factor 3
General Specifications
Display (LCD) Digital readout: 3300 count
Display Refresh Rate 4 times/sec
Maximum Conductor Diameter 1.6" (40 mm)
Battery 2 x AA, IEC LR6, NEDA 15A, alkaline
Battery Life Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic Shut-Down Meter automatically shuts down after 15 minutes of inactivity
Operating Temperature 14 to 122�F (-10 to 50�C)
Storage Temperature -40 to 140�F (-40 to 60�C)
Operating Humidity Non-condensing at <50�F (<10�C)
90% relative humidity at 50 to 86�F (10 to 30�C)
75% relative humidity at 86 to 104�F (30 to 40�C)
45% relative humidity at 104 to 122�F (40 to 50�C)
Operating Altitude 6561.7' (2000 m)
Storage Altitude 39,370.1' (12,000 m)
Dimensions 9.2 x 4 x 1.8" (234 x 101 x 46 mm)
Weight 1.1 lbs (500 g)
Safety Specifications
General Safety IEC 61010-1: Pollution Degree 2
Measurement Safety IEC 61010-2-032: CAT III 600 V/CAT IV 300 V
Current Sensor Action Category IEC 61557-13: Class 2, ?30 A/m
True RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms
1.6" (40 mm) jaw opening
Highest resolution of 1 A, measure up to 60 A
Selectable filter function removes unwanted noise
Max/Min/Average readings and hold function
Forward-facing LED work light for use in dark wiring cabinets
Backlit display; auto backlight off and auto power off for extended battery life
Internal Memory Logging: up to 65,000 measurement points
CAT III 600 V safety rating
This True RMS leakage current clamp meter helps users detect, document, record, and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment offline.
It features a large 1.6" (40 mm) diameter jaw for work with large conductors.
The jaw is fully shielded to capture very small leakage signals and minimize external electromagnetic interference.
Also, this product offers wireless data connectivity via Fluke Connect, helping you to identify potential problems before they turn into major failures.