21% off

Kusam Meco KM 877 - 6000 Counts True RMS Digital Insulation Multimeter

27,719 35,000 21% off

NET AMOUNT Rs.23,491.00 +18% GST APPLICABLE

Kusam Meco KM 877 - 6000 Counts True RMS Digital Insulation Multimeter

Brand : Kusam Meco

Model : KM 877

Operating Temperature : -10°C ~ 40°C

Relative Humidity : Maximum relative humidity 90% for temperature up to 28°decreasing linearly to 50% relative humidity at 40°C.

Pollution degree : 2

Storage Temperature : -20°C ~ 60°C, < 80% R.H. (with battery removed)

Altitude : Operating below 2000m

Warranty : 1Year

Kusam Meco KM 877 - 6000 Counts True RMS Digital Insulation Multimeter Specifications PDF  Download 


20 In Stock
Inquiry  
Deliver to

 VFD V & Hz readings.

 Paper White Backlight LCD Display

 Record MAX / MIN readings.

 Display Hold Function.

 Dual Digital Display.

 PI & DAR Function.

Autoranging.

Pass /Fail Insulation Resistance Compare function; 12 selectable Preset Values.

 LOCK-Test mode for Insulation Resistance & Earth Continuity Test.

 BeepJack  audible & visible input warning.

 Remote Probe for insulation Resistance & Earth Continuity Test.

Functions : DC/AC Voltage , VFD AC Voltage, Insulation Resisitance, Resistance, Earth Continuity Test, Hz Line Level Frequency

Specifications :
Sensing : AC, True RMS
Display : 3-5/6 digits 6000 Counts Backlight LCD Display.
61 Segments Analog Bar Graph : 60 per second max.
Auto or Manual-ranging mode.
Auto Power Off.
Polarity : Automatic
Update Rate : 5 per second nominal
Earth Continuity Test : 110mA @20 ? range, 220mA @2.0 ? range.
Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at room temperature.
These are standard test of 1 ? with a duty cycle of 5 seconds on & 25 seconds off.

Insulation Resistance @ 1mA Test Current :
50V output Voltage :25mA, 100V output Voltage : 45mA
250V output Voltage : 85mA, 500V output Voltage : 170mA
1000V output Voltage : 440mA
Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature.
These are standard tests of 1000V into 1M? with a duty cycle of 5 seconds on and 25 seconds off.

Operating Temperature : -10°C ~ 40CRelative Humidity : Maximum relative humidity 90% for temperature up to 28°C
decreasing linearly to 50% relative humidity at 40°C.
Pollution degree : 2
IP Rating : IP40
Storage Temperature : -20°C ~ 60°C, < 80% R.H. (with battery removed)
Altitude : Operating below 2000m
Temperature Coefficient : Nominal 0.15 x (specified accuracy)/ °C @(-10°C~18°C or 28°C~40°C), or otherwise specified.
Low Battery : approx. 4.6V
Power Supply : Four Alkaline AA batteries
Power Consumption : 4.5mA typical except : ACV +Hz & VFD ACV +Hz : 7.0mA
APO Timing : Idle for 20 minutes
APO Consumption : 50 µA typical
Dimension: 208(L) X 103(W) X 64.5(H) mm with holster
Weight : 635 gm with holster.

IP Rating : IP40
Temperature Coefficient : Nominal 0.15 x (specified accuracy)/ °C @(-10°C~18°C or 28°C~40°C), or otherwise specified.
Low Battery : approx. 4.6V
Power Supply : Four Alkaline AA batteries. buy Vegabazaar available on it. Do calibration any of instruments at Vega Calibrations and Validations Services LLP
Weight 2.1 kg
Dimensions 122 × 145 × 321 cm